Changing temperature monitoring systems in a pharma warehouse
A cold room can keep the same name for years while its probes, loggers and monitoring software change. If an alarm begins on the old system and the investigation closes after the switch, quality staff need to be able to follow the event across both.
Frigalis Published
One cold room, two measurement histories
Consider a distributor replacing the monitoring system in one cold room. During a short overlap, the outgoing logger and a new probe record side by side. Both carry the room name. Each has an identifier and a calibration record. Their sampling intervals can also differ. A location history that shows when each channel was assigned to the room helps explain why two readings can appear for the same minute.
The order in which readings arrive can also change. A logger might take a reading before the handover and transmit it after reconnecting. The measurement time places the reading in the room’s history. The time it reached the server helps explain what the duty team could see when it responded.
An alarm that spans the handover
Suppose the old system alerts the on-call team just before the handover. A technician acknowledges the alarm there. The first in-range reading after the handover comes from the new probe. It establishes that the temperature was within range at that probe at the time of measurement. The original alarm record shows who acknowledged it and when. The deviation record can link to the quality assessment and the decision on any stock potentially affected.
For live monitoring, the site and supplier first need to establish whether the installed logger or gateway can provide an authorised feed at the required interval. During the overlap, the existing call-out procedure can remain active while a controlled test follows an alarm from the new source through to acknowledgement by the designated on-call recipient. The site can then record when the new system takes over.
What remains accessible after the switch
A spreadsheet export can provide readings for selected sensors and a time window. A sensor report may also include events and the time zone used to display them. For a historical review, the difference matters. A reader following the alarm may also need the original acknowledgement and the audit trail behind a configuration change.
For the cold room, a useful comparison is the final hour before handover and the first hour after it. Can a reviewer retrieve both channels, identify missing intervals and trace the alarm to its original acknowledgement? An archive the site can still query is one option. A migration is another, with the transferred records checked against the source for content and meaning. For pharmaceutical wholesale distribution, EU GDP section 3.2.1 links the placement of temperature monitors to temperature mapping. Section 3.3.1 calls for periodic checks that stored data remain accessible.
A starting point for a Frigalis pilot
Frigalis is developing a standalone monitoring application for pharmaceutical manufacturers and distributors and is looking for partners for its first pilots in Swiss distribution. A first discussion could start with a closed deviation from one cold room and a site-approved export. Together, the teams could test whether a reviewer can trace the readings, acknowledgements and decision back to their sources. Moving live alarms or connecting a warehouse system would require a separate scope.